2. 200-Pin Male OR 4X50-Pin to 200-Pin, 60 VDC LFH Switch Cable—The LFH200 cable provides connectivity to the NI PXI-2569, PXI-2570, PXI-2571, PXI-2575, SCXI-1169, and SCXI-1175 switch modules. All three options have a 200-Pin, Male LFH front end connection. The following tables list the pin assignments for the SH200LFH-4xDB50F-C cable. The supply to each DUT can be switched on and off individually over high side switches controlled with a relay card (PXI-2571), the sense of the suppy is switched as well with the relay card to the selected DUT. The following items are changes in NI-SWITCH 4. PXI/PXIe-2543; PXI/PXIe-2544; PXI. PXI-2571 / 778572-71 - PXI Relay - 20" VPC Cable Assembly - TriPaddle 256 (Relay Cable Assembly Solution) The PXI‑2571 is a general-purpose switch module that features independent single‑pole double‑throw (SPDT) Form C armature relays. Hello, I am using NI PXIe-8360 along with PXI-2571, PXIe-6341, PXI-2720, PXI-8433/2 and PXI6722 (Chassis - NI PXI-1062Q). pxi-2522 PXI-2521 Company advantage service: 1. Each relay channel has a normally closed (NC), normally open (NO), and common (COM) terminal. NI-SWITCH is an interchangeable virtual instrument (IVI)–compliant instrument driver, and it features a set of operations and properties that exercise the functionality of the switch module and includes an interactive soft front panel and examples. If it is a PXI target you should add a PXI chassis and then an R-Series card. The PXI‑2567 includes overcurrent, overvoltage. 8 MS/s Isolated Digitizer, PXI Digital Multimeter —The PXI‑4071 is a high-performance 7½‑digit, 1,000 V DMM that provides the measurement. mlpkginstall) There are several ways to initiate the Support Package Installer from these files: Open the . All three options have a 200-Pin, Male LFH front end connection. 1 in. Author. Diversified models and products, and all kinds of rare and discontinued products 4. NI-SWITCH 18. Each relay channel has a normally closed (NC), normally open (NO), and common (COM) terminal. Each option has a different back end connection. Industry leading, price advantage, quality assurance 3. 1は、次のオペレーティングシステムをサポートしています。. Related Products: NI PXI-5421 Output Module NI PXI-5421 Output Module. PXI-2571 Driver. Click on that. NI. PXI/PXIe-2540; PXI/PXIe-2541; PXI RF Multiplexer Switch Module. The cable is available in three versions. jpg","path":"1. 4- Search the PXI-2800 and click in Ok. hwdb/20-OUI. 783139-02 Cable and Wire from NATIONAL INSTRUMENTS 2-Year Warranty - SWITCH CABLE, 2M, SWITCH MODULE, ACCESSORY TYPE:SWITCH CABLE, FOR USE WITH:NI PXI-2569, PXI-2570, PXI-2571, PXI-2575, SCXI-1169 AND SCXI-1175 SWITCH. NI-XNET CAN HS/FD cRIO-9030 NI 9144 NI PXIe-2526 NI 9246 PXIe-4137 NI 9251 with mini XLR NI 9436 NI 9224 ($) NI 9266 NI 9266 with DSUB NI 9351 cRIO-9040 NI PXIe-5113 NI-5165 NI 9252 NI 9231 cRIO-9055 cRIO-9046 cRIO-9263 with DSUB cFP-2200 cFP-DIO-550 cFP-CB-1 cFP-DO-401 cFP-AI-110 PXI-2521 cRIO-FRC II cRIO-9862 cRIO-9516. Manufacturer: National Instruments; Model: PXI; PXI-2571, 66-Channel, PXI Relay Module National Instruments PXI-2571 PXI Relay ModuleThe NI PXI-2571 (Part Number: 778572-71) is a 66-channel, broadly useful switch module. NI-SWITCH is an NI instrument driver that you can use to control and configure NI switches. All specifications are subject to change without notice. Each relay channel has a normally closed (NC), normally open (NO), and common (COM) terminal. ; Download and save the file (the default option for some Internet browsers), and open it directly from. Has been engaged in industrial control industry for a long time, with a large number of inventories. 1 Readme. The LFH200 cable is available in three configurations: • SH200LFH-4xDB50F-C—Recommended for use with the PXI-2569. 直接從 IVI 基金會網站 安裝最新的 IVI . Has been engaged in industrial control industry for a long time, with a large number of inventories. Use this guide to match your NI General Purpose Relay and Relay Driver models PXI or PXI Express (PXIe) device with a compatible cable and accessory to meet the needs of your application, whether you are creating a new configuration, replacing or expanding your current configuration, or verifying that existing parts can be used in a different. Note Tightening the top and bottom mounting screws increases mechanical stability and also electrically connects the front panel to the chassis, which can improve the signal quality and electromagnetic. The PXI-2571 is a general-purpose switch module that features independent single-pole double-throw (SPDT) Form C armature relays. NI PXIe-2790 . Home Support Documentation Dimensional Drawings PXI-2571 Dimensional Drawings PXI-2571 Dimensional Drawings This page provides dimensional drawings for the PXI-2571. ni-switchドライバには、niのすべてのpxi、pxie、scxiスイッチ製品のドライバサポートとドキュメントが含まれています。 NI-SWITCHはIVI準拠のドライバであり、これを使用することでNIスイッチモジュールで標準のIVIクラスコマンドを使用できます。Why Max is not having option to simulate the cRIO, PXI and Instruments such as DMM, DC POWER, NI SWITCH. Each option has a different back end connection. GE DS200DMCBG1AKG Processor. NC0 NC1 NO CONNECT NC2 NC 3 NC4 150 151 149 152 148. PXI/PXIe-2540; PXI/PXIe-2541; PXI RF Multiplexer Switch Module. Overview. NI PXI-2569, PXI-2570, PXI-2571, PXI-2575, SCXI-1169 and SCXI-1175 Switch Modules Product Range: LFH200 Find similar products Choose and modify the attributes above to find similar products. ; Download and save the file (the default option for some Internet browsers), and open it directly from. NO50. The PXI-2570 Relay Module is also rated for Measurement Category I and can carry signal voltages to a maximum of 100 V. NI 9212 NI-XNET CAN HS cRIO-9031 cRIO-9425 with DSUB PXIe-2737 cRIO-9472 NI PXI-1033 NI PXI-1031 cRIO-9065 PXIe-1062 NI 9247 NI 9145 NI 9207, NI 9208, NI 9209 with DSUB, NI 9210 with mini TC, NI 9775 cFP-CAL NI 9228 ($) cDAQ-9185 cRIO-9042 PXIe-1084 cRIO-9056 NI PXIe-5163 PXIe-5110 cRIO-9208 w. The first option has a 200-Pin, Male Bare Wire back end. The first option has a 200-Pin, Male Bare Wire back end. The first option has a 200-Pin, Male Bare Wire back end. PXI/PXIe. All three options have a 200-Pin, Male LFH front end connection. ni pxi/pxie-2532に追加された1つのトポロジおよびni tb-2646端子台のサポート。 ni-switch 4. NI-9403 Letter of Volatility. The first option has a 200-Pin, Male Bare Wire back end. The PXI‑2567 is an external relay driver that works with internal or external power sources. The NI PXI-2571 PXI Relay Module from National Instruments (Part Number: 778572-71) is a versatile switch module with 66 channels. All three options have a 200-Pin, Male LFH front end connection. Farnell România propune oferte rapide de preț, expediere în aceeași zi, livrare rapidă, un inventar bogat, fișe tehnice și asistență tehnică. 0. Industry leading, price advantage, quality assurance 3. NI-SWITCH is an interchangeable virtual instrument (IVI)–compliant instrument driver, and it features a set of operations and properties that exercise the functionality of the switch module and includes an interactive soft front panel and examples. The following items are changes in NI-SWITCH 4. The NI PXI-2570 optimizes relay density in one PXI slot. Twisted Pair Groupings for the PXI-2571 Refer to the NI Switches Help for a complete listing of channel names and pinouts. pxi-2571; pxi-2586; pxi rfマトリクススイッチモジュール. Test and Measurement Accessories are in stock at DigiKey. All three options have a 200-Pin, Male LFH front end connection. jpg","contentType":"file"},{"name":"10. 783139-02 – Specialized Cable for use with NI PXI-2569, PXI-2570, PXI-2571, PXI-2575, SCXI-1169, SCXI-1175 from NI. (Optional) Connect any DAQ accessories, such as connector blocks, that are available using a suitable cable. The National Instruments PXI-2571 is a general-purpose switch module that features independent single-pole double-throw (SPDT) Form C armature relays. All three options have a 200-Pin, Male LFH front end connection. This hardware diagram will show the names for each relay on the module. com Do I need to modify my DMM/Switch code when upgrading from PXI-4060 to PXI-4070?. There are three different options for this cable. Figure 7 illustrates how this pairing relates to the pins on the PXI-2571. NI-SWITCH Issue Details How do the niSwitch Wait For Debounce VI know if the hardware if the debounce is already settled? What is the behavior or steps behind it? Solution What the function does is block until the settling time has expired. 機械的リレー寿命 - これは、リレーが機械的な完全性を維持しながら実行することが想定できる動作回数です。. NI-SWITCH is an NI instrument driver that you can use to control and configure NI switches. 概要. NI-SWITCH is an interchangeable virtual instrument (IVI)–compliant. Buy 778572-71 - Ni - Relay Module, PXI-2571, 35MHz, SPDT, 66 Channel, 1A, 100V. 1 Other Microsoft Visual Studio Issue Details I downloaded and installed a . Open a service request. Contact us. Perspectives. The LabVIEW project comes with some default hardware, you should move the folders and. 5 Readme. Dynamic power budget for NI SwitchBlock cards and carriers. pxi-2522 PXI-2521 Company advantage service: 1. NI PXI-2571 66-Channel 1A SPDT Relay Module National Instruments PXI-2571, RELAY MODULE, SPDT, 66-CH; Product Type:PXI Relay Module; Contact Configuration:SPDT; Bus Connector Type:PXI Hybrid; Switching Voltage Max:100V; Switching Current Max:1A; Bandwidth:35MHz; For Use With:NI PXI Controller RoHS Compliant: YesNI-SWITCH 18. The NI device weighs 5. NI-SWITCH Drops Support for Windows 7 (32- and 64-Bit), Windows Server 2008 R2, and All 32-Bit Windows Operating Systems in 2021. PXI Express Single-Slot Module 4. NI PXI-2798 . All three options have a 200-Pin, Male LFH front end connection. It has a recommended operating temperature. NET Shared Components directly from the IVI Foundation Website. NET Class Libraries 1. 修復NI-DMM或NI-SWITCH驅動。. The following tables list the pin assignments for the SH200LFH-4xDB50F-C cable. Symbol Description Certification; EU & UK Declarations of Conformity (DoC) PDF KC, EMC: PDF UL, Product Safety: View:概要. SH200LFH-4xDB50F-S—Recommended for use with the PXI-2575 or SCXI-1175. Industry leading, price advantage, quality assurance 3. The first option has a 200-Pin, Male Bare Wire back end. Each option has a different back end connection. 200-Pin Male OR 4X50-Pin to 200-Pin, 60 VDC LFH Switch Cable—The LFH200 cable provides connectivity to the NI PXI-2569, PXI-2570, PXI-2571, PXI-2575, SCXI-1169, and SCXI-1175 switch modules. There are three different options for this cable. (Optional) Connect any DAQ accessories, such as connector blocks, that are available using a suitable cable. IDPXI-2571 PXI-2586 PXIe-2569 Driver. NI-SWITCH Issue Details. An example of the hardware diagram in NI Switches Help for the NI PXI-2568 module is shown below. Each option has a different back end connection. 15 days free replacement for quality problems价格不含税。. 2. NI-DMM NI-SWITCH NI-SWITCH . 3. ) Weight 174 g. Together, the two modules create a reconfigurable instrument that you can program with. 4. All specifications are subject to change without notice. Figure 2. Highlighting free SPDT (Form C) relays, the PXI-2571 expands relay density in a solitary PXI slot. 8 in. PXI-2571 66 Channel, 1A SPDT Relay Module. Each relay contains a normally closed (NC), normally open (NO), and common terminal (COM), and can deal with up to 100 VDC/100 VAC or up to 1 A current. RAM—1 GB RAM(32ビット)または2 GB RAM(64ビット). All three options have a 200-Pin, Male LFH front end connection. The LFH200 cable provides connectivity to the NI PXI-2569, PXI-2570, PXI-2571, PXI-2575, SCXI-1169, and SCXI-1175 switch modules. Farnell България предлага бързи оферти, изпращане в същия ден, бърза доставка, голям избор на инвентар, информационни листове и техническа поддръжка. 200-Pin Male OR 4X50-Pin to 200-Pin, 60 VDC LFH Switch Cable—The LFH200 cable provides connectivity to the NI PXI-2569, PXI-2570, PXI-2571, PXI-2575, SCXI-1169, and SCXI-1175 switch modules. Industry leading, price advantage, quality assurance 3. Is this correct test panel for pxi-2720? 3. The NI device weighs 5. driver for ni switching instruments national instruments switching instruments supported models: ni 2810, ni 2811, ni 2812, ni 2813, ni 2814, ni 2815, ni 2816, ni 2817, ni 2833, ni 2834, ni pxi-2501, ni pxi-2503, ni pxi-2510, ni pxi/pxie-2512, ni pxi/pxie-2514, ni pxi/pxie-2515, ni pxi-2520, ni pxi-2521, ni pxi-2522, ni pxi-2523, ni pxi/pxie-2527, ni. There are three different options for this cable. All three options have a 200-Pin, Male LFH front end connection. Related Links. The LFH200 cable provides connectivity to the NI PXI-2569, PXI-2570, PXI-2571, PXI-2575, SCXI-1169, and SCXI-1175 switch modules. From the popup menu select PXI Chassis and click Next. In this example, the relay names are K0 through K30. Problem: There are two modules in slots 7 and 8 of the PXIe-1082 chassis; However, their throughput seems to be imbalanced with each other. Industries. NI 9212 NI-XNET CAN HS cRIO-9031 cRIO-9425 with DSUB PXIe-2737 cRIO-9472 NI PXI-1033 NI PXI-1031 cRIO-9065 PXIe-1062 NI 9247 NI 9145 NI 9207, NI 9208, NI 9209 with DSUB, NI 9210 with mini TC, NI 9775 cFP-CAL NI 9228 ($) cDAQ-9185 cRIO-9042 PXIe-1084 cRIO-9056 NI PXIe-5163 PXIe-5110 cRIO-9208 w. 2. ℹ️ Download National Instruments LFH200 Manual (Total Pages: 35) for free in PDF. ni pxi/pxie-2532に追加された1つのトポロジおよびni tb-2646端子台のサポート。 ni-switch 4. 5 x 0. Hi I have installed Veristand 2014 on my PC connected to a NA PXI8109 including 1 PXI-2571 and 1 PXI-6514: when I start the Hardware Discovery wizard. Newark. Diversified models and products, and all kinds of rare and discontinued products 4. . 查找NI工程师编写的常见问题. NI PXI-2799. They offer various configurations and features, such as high current, high voltage, and high density. Twisted Pair Groupings for the PXI-2571 Refer to the NI Switches Help for a complete listing of channel names and pinouts. PXI card installed : PXI 2720(slot2), PXIe-6341(slot3- it is working), PXI-2571(slot 5), PXI-8430(Slot6), PXI-8433/2(Slot7) When we checked th. 200-Pin Male OR 4X50-pin to 200-Pin, Male LFH Switch Cable200-Pin Male OR 4X50-Pin to 200-Pin, 60 VDC LFH Switch Cable—The LFH200 cable provides connectivity to the NI PXI-2569, PXI-2570, PXI-2571, PXI-2575, SCXI-1169, and SCXI-1175 switch modules. National Instruments PXI-2571 (778572-71) used. Twisted Pair Groupings for the PXI-2571 Refer to the NI Switches Help for a complete listing of channel names and pinouts. 2. Pricing and Availability on millions of electronic components from Digi-Key Electronics. However, when I try to run the included. This module can withstand up to 500 V impulse voltage. NI 2811. The following tables list the pin assignments for the SH200LFH-4xDB50F-C cable. 7. pxi-2522 PXI-2521 Company advantage service: 1. All three options have a 200-Pin, Male LFH front end connection. PXI-2571 / 778572-71 - NI (National Instruments) 66-Channel, 1 A, SPDT PXI Relay Module—The PXI‑2571 is a general-purpose switch module that features independent single‑pole double‑throw (SPDT) Form C armature relays. Product iQ offers professional level information and is free for most users. 15 days free replacement for quality problemsINSTALLATION INSTRUCTIONS LFH200 Cable. 1. Buy PXI Relay Modules. Open a service request. Find Agilent - Keysight, National Instruments, and RTS for sale on Machinio. or send us a message. 12658704 Canada Inc. NI 9237 Letter of Volatility. ni-switch 問題. This document lists specifications for the NI PXI-2571 (PXI-2571) general-purpose relay module. The toolbox supports NI-SWITCH devices using the NI-SWITCH driver version 4. And I need to use "NI-USB 6001" for other test purpose. Overview. PXI Arbitrary Waveform Generators (14) Waveform Signal Generators (14) Relay Testers (11) Current Meters (10) Current Transformers (10) ATE Software (6) Drivers (6) Open Circuit (6) PXI Multiplexers (6) Test Light (6) Automated Test Equipment Software (5) General Purpose Switch (5)From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Overview. There are three different options for this cable. You can request repair, schedule calibration, or get technical support. Each relay channel has a normally closed (NC), normally open (NO), and common (COM) terminal. Letters of Volatility describe the type of data stored in volatile & nonvolatile memory on NI. 2. All three options have a 200-Pin, Male LFH front end connection. Secure the module front panel to the chassis using the front-panel mounting screws. Phone number: 1-877-854-3577 — Email: CEC@ul. Figure 7. 继电器机械寿命 - 是指在保证机械结构完整的前提下继电器能够完成的操作次数。. Anyone can obtain information about the validity of a given certification by contacting the UL Customer Experience Center. Figure 7. com Terms and Definitions User Accessible User accessible memory allows the user to directly write or modify the contents of the memory during normal instrument operation. Company Profile | Victoria, BC, Canada | Competitors, Financials & Contacts - Dun & BradstreetSpecialties: National Access Cannabis provides access and education to Canadians looking to obtain Legal Medical Cannabis. Each relay channel has a normally closed (NC), normally open (NO), and common (COM) terminal. NI-SWITCH is an NI instrument driver that you can use to control and configure NI switches. The LFH200 cable provides connectivity to the NI PXI-2569, PXI-2570, PXI-2571, PXI-2575, SCXI-1169, and SCXI-1175 switch modules. 66-Channel, 1 A, SPDT PXI Relay Module. Farnell Israel offers fast quotes, same day dispatch, fast delivery, wide inventory, datasheets & technical support. NI-XNET CAN HS/FD cRIO-9030 NI 9144 NI PXIe-2526 NI 9246 PXIe-4137 NI 9251 with mini XLR NI 9436 NI 9224 ($) NI 9266 NI 9266 with DSUB NI 9351 cRIO-9040 NI PXIe-5113 NI-5165 NI 9252 NI 9231 cRIO-9055 cRIO-9046 cRIO-9263 with DSUB cFP-2200 cFP-DIO-550 cFP-CB-1 cFP-DO-401 cFP-AI-110 PXI-2521 cRIO-FRC II cRIO-9862 cRIO-9516. The PXI‑2571 is a general-purpose switch module that features independent single‑pole double‑throw (SPDT) Form C armature relays. Diversified models and products, and all kinds of rare and discontinued products 4. . Overview. SH200LFH-BARE WIRE Recommended for termination other than 50-pin female D-SUB. An. Manufacturer: Allen-Bradley Model: 700 Allen Bradley MPN: 700DC-P400Z12 NEW DC Control Relay Item is new in box Box Dimensions: 8" x 4" x 3" 30 day warranty on all purchases. PXI-6224 M-Series Multifunction DAQ Card. All three options have a 200-Pin, Male LFH front end connection. PXI-2571 NI module PXI-2571 NI module Module Clips Drive controller servo motor Contact: Mr. 继电器期望寿命分为两大类:. NC0 NC1 NO CONNECT NC2 NC3 NC4 150 151 149 152. Next expand the menu so that you can choose the appropriate PXI Bus for your application. 2- Right-click in Devices and Interfaces and select Create New. Overview. 200-Pin Male OR 4X50-Pin to 200-Pin, 60 VDC LFH Switch CableFrom troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. The NI-SWITCH driver contains both LabVIEW and text-based APIs for programming NI Switches. pxi‑2571は、独立したspdt(c接点式)アーマチュアリレーを装備した、汎用スイッチモジュールです。 各リレーチャネルには、NC(ノーマルクローズ)、NO(ノーマルオープン)、COM(コモン)の各端子が備わっています。The PXIe‑7971 provides flexible, customizable I/O for LabVIEW FPGA. National Instruments has several brands around the world that distributors may use as alternate names. com. All three options have a 200-Pin, Male LFH front end connection. 電気的. The PXI-2571 is a general-purpose switch module that features independent single-pole double-throw (SPDT) Form C armature relays. LFH200, SWITCH CABLE, 2M; Accessory Type:Switch Cable; For Use With:NI PXI-2569, PXI-2570, PXI-2571, PXI-2575, SCXI-1169 and SCXI-1175 Switch Modules; Product Range:LFH200 RoHS Compliant: Yes. Clicking the Get Support Package button provides the support package install file: ([filename]. You can request repair, schedule calibration, or get technical support. 5. NET 共享組件。. NI-SWITCH is an interchangeable virtual instrument (IVI)–compliant instrument driver, and it features a set of operations. PXI-2571; PXI-2586; PXI RF Matrix Switch Module. All three options have a 200-Pin, Male LFH front end connection. NI-SWITCH software for the Linux/x86 64-bit architecture has the following requirements: 1 GHz. 8 x 5. NI PXI-2570/71 March 2017 Notice: This document. Modulo di relay PXI SPDT a 66 canali, 1 A. All three options have a 200-Pin, Male LFH front end connection. Diversified models and products, and all kinds of rare and discontinued products 4. 5A, 30V. The first option has a 200-Pin, Male Bare Wire back end. Diversified models and products, and all kinds of rare and discontinued products 4. MXI express card : NI PXIe-8360 (In my Notebook computer : 8360 card, OS: windows 7 3. All three options have a 200-Pin, Male LFH front end connection. Options. PXI-2570 PXI-2571 PXI-2586 PXIe-2569 Driver. PXI-2571; PXI-2586; PXI RF Matrix Switch Module. Featuring compact reed relays with switching speeds up to 2,000 cycles/s, the PXIe‑2532B can be configured in more than 10 matrix topologies by using different terminal block. Fixed an issue where the NI PXI-2571 did not honor user-defined settling times. The LFH200 cable provides connectivity to the NI PXI-2569, PXI-2570, PXI-2571, PXI-2575, SCXI-1169, and SCXI-1175 switch modules. Technical Documents (1) Technical Data Sheet EN Product Overview. The LFH200 cable provides connectivity to the NI PXI-2569, PXI-2570, PXI-2571, PXI-2575, SCXI-1169, and SCXI-1175 switch modules. Highlighting free SPDT (Form C) relays, the PXI-2571 expands relay density in a solitary PXI slot. 5500 for Availability. このファイルには、インストール手順、新機能、修正された主なバグのリスト、および既知の問題など、NI-SWITCHに関する重要な情報が記載されています。PCI-7330 Controller module, NI, PCI-7330 Controller module PCI-7330 Controller module Module Clips Drive controller servo motor Contact: Mr. Each option has a different back end. Member 12-10-2013 12:28 PM. PXI-2571 PXI-2586. National Instruments 192607-71. PXI/PXIe-2540; PXI/PXIe-2541; PXI RF Multiplexer Switch Module. NI PXI-2569/2570/2571/2575 or SCXI-1169/1175 switch module and documentation Connecting the LFH200 Cable Complete the following steps to connect the LFH200 cable to your switch module and application. The first option has a 200-Pin, Male Bare Wire back end. SH200LFH-BARE WIRE—Recommended for termination other than 50-pin female D-SUB. プロセッサ—1 GHz以上の32ビット(x86)または64ビット(x64)プロセッサ. Featuring compact reed relays with switching speeds up to 2,000 cycles/s, the PXIe‑2532B can be configured in more than 10 matrix topologies by using different terminal block. com. 5 oz, and measures 8. Visit ni. NI-9205 Letter of Volatility. Manufacturer: National Instruments 192607-71 | NI-9201, 8-Channel, 12 Bit, C Series Voltage Input ModuleThe NI-SWITCH driver provides driver support and documentation for all of NI's PXI, PXIe, and SCXI Switch products. All three options have a 200-Pin, Male LFH front end connection. Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty. 200-Pin Male OR 4X50-Pin to 200-Pin, 60 VDC LFH Switch Cable —The LFH200 cable provides connectivity to the NI PXI-2569, PXI-2570, PXI-2571, PXI-2575, SCXI-1169, and SCXI-1175 switch modules. Each relay channel has a normally closed (NC), normally open (NO), and common (COM) terminal. Mark as New; Bookmark; Subscribe; Mute; Subscribe to RSS Feed; Permalink; Print; Report to a Moderator; Hello, I am setting the system with. PXI power requirement 6 W at 5 V 2. The first option has a 200-Pin, Male Bare Wire back end. NI-SWITCH is an IVI-compliant driver that allows NI Switch modules to be used with standard IVI Class commands. jpg","contentType. 3 includes the following new features: Support for the NI PXI-2530B and NI PXI-2571 modules. The PXIe‑2532B is a high-density PXI matrix switch module built to serve high‑channel‑count automated test systems. Each relay channel has a normally closed (NC), normally open (NO), and common (COM) terminal. There are three different options for this cable. Join Product iQ. Once your test data is in MATLAB, you can analyze and visualize that data for tasks such as signal processing, statistical analysis, digital filtering, and curve fitting. 779038-01 Computer from NATIONAL INSTRUMENTS In Stock, Order Now! Same Day Shipping, 2-Year Warranty, Radwell Repairs - SWITCH CABLE, 2M, SWITCH MODULE, ACCESSORY TYPE:SWITCH CABLE, FOR USE WITH:NI PXI-2569, PXI-2570, PXI-2571, PXI-2575, SCXI-1169 AND SCXI-1175 SWITCH MODULES, PRODUCT RANGE:LFH200 ROHS COMPLIANT: YES The PXI-2571 is a general-purpose switch module that features independent single-pole double-throw (SPDT) Form C armature relays. Each option has a different back end connection. NI LabVIEW 2011 Service Pack 1 is the latest version of the graphical development software supported by this driver set. Has been engaged in industrial control industry for a long time, with a large number of inventories. Solution. Each option has a different back end connection. Then click Finish once you are done. If I click the test panel, "Switch Soft Panel" appears with topology - "2720/independent"? It looks like swich instead of testing programmable resistor. Caution The LFH200 cable has a maximum voltage rating of 60 VDC. NI-XNET CAN HS/FD cRIO-9030 NI 9144 NI PXIe-2526 NI 9246 PXIe-4137 NI 9251 with mini XLR NI 9436 NI 9224 ($) NI 9266 NI 9266 with DSUB NI 9351 cRIO-9040 NI PXIe-5113 NI-5165 NI 9252 NI 9231 cRIO-9055 cRIO-9046 cRIO-9263 with DSUB cFP-2200 cFP-DIO-550 cFP-CB-1 cFP-DO-401 cFP-AI-110 PXI-2521 cRIO-FRC II cRIO-9862 cRIO-9516. You can request repair, schedule calibration, or get technical support. UUT. 2 Auto Zero disabled, except 7½ digits, measured on a 10 V and 10 kΩ range. 3. NI-SWITCH 19. NO50. PXI-4071 DC Speeds, Nominal Digits Bits Max Sampling Rate1 (Digitizer) Reading Rate2 (DMM) 7½ 26 N/A 7 S/s 6½ 22 100 S/s 100 S/s 5½ 18 5 kS/s 3 kS/s 4½ 15 20 kS/s 7 kS/s 3 10 1. Each option has a different back end. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. There are three different options for this cable. An example of the hardware diagram in NI Switches Help for the NI PXI-2568 module is shown below. 2x Mode Drive Formats 01 2 11 1 10 0 00 4 11 5 XX 3 Indeterminate State Return to Low (RL) Return to High (RH) Non-Return (NR) Pin State Vector Cycle e Off e On e Data e Data e Data NO50. PXI‑2571是一款通用开关模块,具有独立的单刀双掷 (SPST) Form C电枢继电器。. Manufacturer Aliases. Industry leading, price advantage, quality assurance 3. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. The PXI‑2570 is a general-purpose switch module that features independent single‑pole double‑throw (SPDT) Form C armature relays. 0. 6 cm × 2. {"payload":{"allShortcutsEnabled":false,"fileTree":{"":{"items":[{"name":"1. Perspectives. The NI PXI-2571 (Part Number: 778572-71) is a 66-channel, broadly useful switch module. NI-SWITCH is an interchangeable virtual instrument (IVI)–compliant instrument driver, and it features a set of operations and properties that exercise the functionality of the switch module and includes an interactive soft front panel and examples. There are three different options for this cable. menu. 7GHz, SPDT, 0. Each relay channel has a normally closed (NC), normally open (NO), and common (COM) terminal. 技術的な問題のトラブルシューティングや推奨製品から、見積りと注文まで、弊社がお手伝いいたします。The LFH200 cable provides connectivity to the NI PXI-2569, PXI-2570, PXI-2571, PXI-2575, SCXI-1169, and SCXI-1175 switch modules. Each option has a different back end. PXI-4071 DC Speeds, Nominal Digits Bits Max Sampling Rate1 (Digitizer) Reading Rate2 (DMM) 7½ 26 N/A 7 S/s 6½ 22 100 S/s 100 S/s 5½ 18 5 kS/s 3 kS/s 4½ 15 20 kS/s 7 kS/s 3 10 1. Build test systems using National Instruments NI-SWITCH hardware. Systems Engineering Software. The first option has a 200-Pin, Male Bare Wire back end. NI-SWITCH 4. This is provided for informational purposes only. PXI-2571 Product Certifications. PXI-2569 PXI-2570 PXI-2571 PXI-2586 PXIe-2569 Issue Details The Expected Relay Life specification for NI electromechanical relay switch modules is described in terms of Mechanical and Electrical. 15 days free replacement for quality problemsVásárlás PXI Relay Modules kategóriában. The PXI-2571 is a general-purpose switch module that features independent single-pole double-throw (SPDT) Form C . Each option has a different back end connection. This page provides dimensional drawings for the PXI-2571. NC0 NC1 NO CONNECT NC2 NC3 NC4 150 151 149 152. Industry leading, price advantage, quality assurance 3. This cable is proposed for connecting the SCXI-1169, SCXI-1175, PXI-2569, PXI-2570, PXI-2571, or PXI-2575 to your system. NI-SWITCH is an NI instrument driver that you can use to control and configure NI switches. The following tables list the pin assignments for the SH200LFH-4xDB50F-C cable. Each relay channel has a normally closed (NC), normally open (NO), and common (COM) terminal. 0 cm (8. Figure 7 illustrates how this pairing relates to the pins on the PXI-2571. Each option has a different back end connection. NET Class Library for NI hardware (such as NI-DMM or NI-SWITCH). 每个继电器通道都具有常闭 (NC)、常开 (NO)和公共 (COM)接线端。. 5 in. NI-SWITCH is an interchangeable virtual instrument (IVI)–compliant. A valid service agreement may be required. The second configuration of the LFH200 Switch Cable comes with 25 un-terminated, stripped, and tinned wires at the device-end or application-end. 6- Select Insert or Remove Simulated Cards within the. The NI PXI-2571 (Part Number: 778572-71) is a 66-channel, broadly useful switch module.